Справочник Пользователя для Pelco C579M
PROGRAMMING AND CONFIGURATION
CM9760-SAT
2-19
3.0 9760 MGR-SAT PROGRAMMING
Before implementing joint 9760-SAT operation, the following configuration files (flat files) must be configured.
1.
The
COMMS
file.
2.
The
CAMERAS
file.
3.
The
LINK CAMERAS
file
and if alarm reporting is invoked
4.
The
ALARMS
file.
The 9760 System Manager program, installed on a PC hard drive connected to the CM9760-CC1 is used to program these files.**
If you received your
If you received your
SAT
unit as part of a system shipment, these files may have already been configured to the extent that it was practical or
that information for your system was available. In any case, you can use the information in the sections that follow to:
1.
Check existing configuration files against requirements, and
2.
To update existing configuration files with the data required to enable 9760-SAT operations.
The following information will be needed to successfully program the flat files associated with
SAT
operation:
1.
You should know the MXB physical port destinations of all tie lines that originate as
SAT
monitor-out lines and terminate as matrix bay
video inputs.
2.
You should know to which physical Sercom port on the controller that the CM9760-SAT is attached.
3.
You should know the link camera assignments for the
SAT
and you should be aware of the receiver types for each connection (PTZ or
fixed).
4.
You should also know the communication parameters for the
SAT
.
Figure 2-6
Programming the COMMS file
** Additional information about the construction and use of configuration files can be found in the CM9760-MGR manual. Installation and manipu-
lation of configuration files with respect to hardware/software updates and changes is covered in detail in the CC1 controller manual.
lation of configuration files with respect to hardware/software updates and changes is covered in detail in the CC1 controller manual.
3.1 COMMS FILE
Start the
System Manager
program,
log in (case-sensitive default: Admin),
left-click on the
left-click on the
9760-Setup
icon, click
on the
Configuration File’s
rectan-
gular
Setup Files
selection bar and
then select the
Comms
tab from
among the
Setup System Configu-
ration
tabs.
Setup the
Comms
file, using the one
illustrated in Figure 2-6 as a guide.
NOTE:
For additional material on the
“nut and bolt” items to be considered
when adding peripheral equipment and/
or software to an existing or new sys-
tem, consult the appropriate sections
of your controller (CM9760-CC1)
manual.
when adding peripheral equipment and/
or software to an existing or new sys-
tem, consult the appropriate sections
of your controller (CM9760-CC1)
manual.