DESCRIPTION
The MRD1400HZ16 is a camera interface control for Pelco’s CC1400HZ16 Series digital
color camera. The unit can be mounted directly to a wall or installed in a DF5 Series dome,
DF8A Series dome, EH2512 Series enclosure, or EH3512 Series enclosure.
The MRD1400HZ16 can be used with the following Pelco controllers and matrix switchers:
Controllers (direct mode only)
MPT9500, CM9760-KBD Series, KBD200A,
and KBD300A
Matrix Switchers
CM6700 Series, CM6800 Series, CM9740
(configured for D or P protocols only)
Series, and CM9760 Series
INSTALLATION
The following items are supplied:
Qty.
Item
1
MRD1400HZ16
1
DF5/DF8/EH2512 Series adapter
1
EH3500 Series adapter
1
4-pin connector
1
Data cable (12 inches)
4
4-40 Phillips button head screws
1
#10 nut and washer
1
Camera sled for EH3500 Series enclosure
DIP SWITCH SETTINGS
BAUD RATE SELECTION
The baud rate must be set for the MRD1400HZ16 to automatically sense D or P protocol.
The default communication rate for the MRD1400HZ16 is 4800 baud. If the system’s control-
ler/switcher uses a different communication rate, change the baud rate of the
MRD1400HZ16 to match the controller/switcher.
To change the baud rate, refer to Figure 1 and Table A.
DATA
IN
RST
DATA
CAM
P
W
R
SW1
MRD1400HZ16
Made in USA
DEFAULT SWITCH
SETTINGS: 6 & 10 ON
ALL OTHER SWITCHES OFF
01218
Figure 1. SW-1 Default Switch Settings
Baud
Rate
NOTE: 
Baud/Address
Settings – If switch settings
are changed while the power
to the MRD unit is ON, push
and hold the reset button for
five seconds and then
release, to recycle power
and accept the new baud/
address setting. Refer to
Figure 4 for the location of
the reset button.
NOTE: 
Dip switches 8, 9,
and 10 are factory set. Do
not change switch positions.
Table A. Baud Rate Switch Settings
                    Switch Setting
6
7
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON