Troubleshooting
 
LED indicators on the front panel of the FT8308 transmitter/FR8308 receiver (refer to  Figure 2 and 
to Figure 3, respectively) allow you to monitor signal status and operating power. Table A 
provides information about the front-panel indicators and associated troubleshooting guidelines.
 
Table A.  
 
Troubleshooting with Front-Panel Indicators 
 
Indicator Color
Meaning
Possible Cause
Corrective Action
Power LED (Pelco badge)
 
Blue Pelco logo 
lights.
Power is being applied 
to the module.
No action required.
Blue Pelco logo does 
not light.
Power is not being 
applied to the module.
Power connection is 
faulty.
Check power 
connection. If module 
is rack mounted, reseat 
module or power 
supply as necessary.
Power supply has 
failed.
Replace power supply.
Loss of power occurs 
due to tripped circuit 
breaker(s), blown 
fuse(s), or faulty 
electrical service.
Check circuit 
breaker(s), fuse(s), or 
electrical service as 
necessary.
 
Video Present LED
 
Green
Incoming video signal 
is present on the 
channel.
No action required.
Red on transmitter 
Incoming video signal 
is not present on the 
channel.
Video source is not 
powered on.
Check power 
connection to the video 
source.
Video source is not 
connected to the 
transmitter.
Check BNC 
connections.
Coaxial cable is 
defective.
Replace cable.
 
(Continued on next page)