CONNECTIONS
Connections to the FT8301A transmitter and the FR8302A receiver are made on the rear panel of the 
modules and consist of the following:
Power connection
NOTES:
A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when 
used as a standalone module. A 12 VDC power supply is provided. If a 24 VAC power 
supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as 
Class 2 and rated as 24 VAC, 200 mA (minimum output).
In extreme temperature conditions, it is recommended that an industrial-rated outdoor 
power supply such as the Pelco WCS1-4 power supply be used.
Fiber connection
Video connection (UTP or BNC)
NOTE:  When connecting to the UTP connector, it is recommended that solid UTP wire rather 
than stranded UTP wire be used. If stranded UTP wire is used, it is recommended that you tin 
the stranded wire.
Figure 5 illustrates FT8301A transmitter connections. Figure 6 illustrates FR8301A receiver 
connections.
Figure 5.   FT8301A Transmitter Connections
POWER CONNECTION
FOR STANDALONE MODULE
FIBER OPTIC CABLE
COAXIAL CABLE
UTP WIRES
OR
POWER/ALARM CONNECTION FOR
RACK-MOUNTED MODULE
+
-
1