Справочник Пользователя для Chamberlain security hd200dm

Скачать
Страница из 40
33
HAVING A PROBLEM?
1.  My door will not close and the light bulbs blink on 
my motor unit: The safety reversing sensor must be 
connected and aligned correctly before the garage door 
opener will move in the down direction.
 • 
 
Verify the safety sensors are properly installed, 
aligned and free of any obstructions. Refer to 
Installation Step 10: Install The Protector System
®
.
 • 
 
Check diagnostic LED for flashes on the motor unit 
then refer to the Diagnostic Chart on the following 
page.
2. My remotes will not activate the door:
 • 
 
Reprogram remotes following the programming 
instructions. Refer to Programming
 • 
 
If remote will still not activate your door, check 
diagnostic LED for flashes on motor unit then refer to 
Diagnostic Chart on the following page.
3.  My door reverses for no apparent reason: Repeat 
safety reverse test after adjustments to force or travel 
limits. The need for occasional adjustment for the force 
and limit settings is normal. Weather conditions in 
particular can affect door travel.
 • 
 
Manually check door for balance or any binding 
problems. 
 • 
Refer 
to 
Adjustment Step 2, Adjust the Force.
4.  My door reverses for no apparent reason after fully 
closing and touching the floor: Repeat safety reverse 
test after adjustments to force or travel limits. The need 
for occasional adjustment for the force and limit settings 
is normal. Weather conditions in particular can affect 
door travel.
 • 
 
Refer to Adjustment Step 1, Adjust the UP and DOWN 
Travel Limits.
 Decrease down travel by turning down 
limit adjustment screw clockwise.
5. My lights will not turn off when door is open:
 • 
 
The garage door opener is equipped with a security 
light feature. This feature activates the light on when 
the safety sensor beam has been obstructed.
Safety Reversing Sensor
Bell Wire
"Learn" 
Button 
LED or 
Diagnostic 
LED
Receiving Eye Safety Reversing
Sensor (Green Indicator Light)
Sending Eye Safety Reversing
Sensor (Amber Indicator Light)
6. My motor unit hums briefly:
 • 
 
First verify that the trolley is against the stop bolt.
 • 
 
Release the door from the opener by pulling the 
Emergency Release Rope.
 • 
 
Manually bring the door to a closed position.
 • 
 
Loosen the chain by adjusting the outer nut 4 to 5 
turns. This relieves the tension.
 • 
 
Run the motor unit from the remote control or door 
control. The trolley should travel towards the door and 
stop. If the trolley re-engages with the door, pull the 
Emergency Release Rope to disengage.
 • 
 
Decrease the UP travel by turning the UP Travel 
adjustment screw 2 full turns away from the arrow.
 • 
 
Re-tighten the outer nut so the chain is a 1/4" (6 mm) 
above the base of the rail. (When the door is 
reconnected and closed, the chain will sag. This is 
normal.)
 • 
 
If the trolley does not move away from the bolt, repeat 
the steps above.