In Box 2 (Traveler box) 
12) Connect SwitchLinc bare wire to ground 
13) Connect SwitchLinc white wire to neutral
 
14) Cap SwitchLinc red wire 
15) Connect SwitchLinc black wire to same color 
traveler from Box 1 that you connected to line 
along with same color traveler wires leading to 
Box 3 
16) Cap the last unused traveler wire(s) 
 
In Box 3 (Load box) 
17) Connect SwitchLinc bare wire to ground 
18) Connect SwitchLinc white wire to neutral 
19) Connect SwitchLinc red wire to load 
20) Connect SwitchLinc black wire to line traveler 
from Box 2 (Line traveled from Box 1 through 2 into 
3 usually black) 
21) Cap unused traveler wire 
22) With LEDs on left, gently place SwitchLincs into 
wall boxes and screw in place 
23) Turn power back on 
SwitchLincs and connected load will  
turn on 
24) Add all SwitchLincs to a group. See “Groups” 
22) Verify all SwitchLincs are working properly by 
tapping each on and off 
All SwitchLincs and the connected load  
will remain in synch 
25) Reinstall wallplates 
 
Local Control 
Follow these instructions to control the connected light/load (as well as any responders) from the 
SwitchLinc paddle.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                      
1
 If neutral is not available in this box; use other unused traveler from Box 1 to carry neutral to Box 2. Label and mark any differently colored wire being connected to neutral with 
a piece of white tape to flag it as neutral. 
Connected Light (and Responders) 
Paddle 
Tap 
Press and hold 
Double-tap 
Top 
On 
(ramped) 
Brighten 
(until release) 
On 
(instant)
 
Bottom 
Off 
(ramped)
 
Dim 
(until release) 
Off 
(instant)
 
Tap for ON, press and hold to brighten 
Tap for OFF, press and hold to dim