Справочник Пользователя для Lucent Technologies P333T

Скачать
Страница из 82
Chapter 4
Installation and Setup
22
Cajun P333T User’s Guide
Assigning Cajun P330’s IP Stack Address 
Note:  All Cajun P330 switches are shipped with the same default IP address. You 
must change the IP address of the master Cajun P330 switch in a stack in order to 
guarantee that the stack has its own unique IP address in the network.
Changing the IP Address using Command Line Interface (CLI, Terminal Emulation)
Use the CLI to assign the Cajun P330 stack an IP address and net mask. The 
CajunView station may establish communications with the stack once this address 
had been assigned and the stack inserted into the network.
1
Establish a serial connection by connecting a terminal to the master Cajun P330 
switch as described in the “Command Line Interface” chapter.
2
When you see the “Welcome to P330” menu and are prompted for a password, 
enter the User Level password
 norm
3
At the 
Console>
 prompt, enter 
enable
 to enter the Privileged level.
4
Enter the password. The default is 
enable
.
5
At the 
Console>(enable)
 prompt, type:
set interface <inband> <vlan> <ip_address> <netmask>
Replace 
<vlan>
,
 <ip_address>
 and
 <netmask> 
with the VLAN, 
IP address and net mask of the stack.
6
Press Enter to save the IP address and net mask.
7
At the 
Console>(enable)
 prompt, enter 
reset
 and press Enter to reset the 
stack. After the Reset, perform login to Privileged level again as described 
above.
8
At the 
Console>(enable)
 prompt, enter 
set ip route 
<dest><gateway>
 where you replace 
<dest>
 and 
<gateway> 
with the 
destination and gateway IP addresses. 
9
Press Enter to save the destination and gateway IP addresses.
Note:  If there are any errors, the new configuration settings will not be saved. To 
save the new configuration settings, you must correct the errors by repeating the 
command.
10 At the 
Console>(enable)
 prompt, type
 exit
 or 
disable 
with the 
password
 
(default password
 norm
 )
 
to exit the Privileged level, and press 
Enter to confirm the command. The prompt changes to 
Console> 
to indicate 
that you are in User level.
11 Exit the CLI session.
12 Insert the Cajun P330 stack into your network.