Table of Zones
NOTE: The Warn Away
®
response does not report on the LED.
Zone No.
Trigger type
Input description
1
Instant
H1/7 BLUE wire. Connect to optional hood/trunk
pins.
pins.
2
Multiplexed
For the onboard shock sensor light impacts
will trigger a Warning Zone response, while
heavy impacts will instantly trigger the full alarm
sequence.
will trigger a Warning Zone response, while
heavy impacts will instantly trigger the full alarm
sequence.
3
Instant Two-stage, or constant
Door switch circuit. H1/8 GREEN or H1/6 VIOLET.
4
Multiplexed Input
Inputs shorter than 0.8 seconds will trigger a
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm
sequence.
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm
sequence.
5
Two-stage (similar to doors)
Ignition input. H1/4 YELLOW.
6
Hood trigger
H2/2 GREY
7
Multiplexed input (sensors)
Inputs shorter than 0.8 seconds will trigger a
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm
sequence.
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm
sequence.
Action
Number of Chirps
Description
Arm
1
System armed
Arm
1 (3 second delay), 1
System armed with Bypass Notification
Disarm
2
System disarmed
Disarm
4
System disarmed with Tamper Alert
Disarm
5
System disarmed NPC
®
active