Справочник Пользователя для Lexicon lexicon480lv4

Скачать
Страница из 150
E-2
Lexicon 480L Owner's Manual
Control Mode - Reference Section
The following list contains a brief description of every
parameter in the control mode, listed in order by page
number.
Page One
STA (Status)
Moving the STA slider displays the current status of a
variety of different controls on the 480L. This control
doesn't permit you to change any settings—it simply
allows you to quickly check out the status of several
480L controls.
CFG (Configuration)
The 480L can run any two of its programs simultane-
ously. The two programs can be used independently,
or they can be connected together internally in any of
several  configurations.  The  CFG  control  is  used  to
choose one of these configurations.
SMP (Sampling Rate)
SMP selects between 44.1 kHz and 48 kHz sampling
rate. Use the higher 48 kHz sampling rate for maximum
audio performance. However, when using digital I/O,
the 44.1 kHz rate may be required to match an external
device.
CLK (Clock Source)
The 480L can generate its own word clock, or it can be
slaved to 48 kHz, 44.1 kHz, and 44.056 kHz external
word  clocks  (through  the  digital  I/O  connector).  For
most applications using the 480L's analog inputs, CLK
should  be  set  to  INTERNAL.  For  most  digital  I/O
applications,  CLK  should  be  set  to  EXTERNAL.  If
EXTERNAL is selected, but an external word clock is
not present at the digital I/O connector, the 480L will
continue to use its internal word clock.
To  determine  if  the  480L  is  correctly  receiving  an
external word clock, move the STATUS slider (slider
one, page one) to display External Word Clock Status.
Important! Do not send external word clock
 to the 480L until after it is powered up.
INP (Input Source)
INP chooses between analog audio input via the main
inputs and digital audio input via the digital I/O port.
Page Two
Page 2 contains controls related to copying and mov-
ing registers. It is sometimes referred to as the register
transporter page.
FUN (Function Setup)
The FUN slider has eight functions:
COPY SETUP
INT TO CART
CART TO INT
MOVE SETUP
CLR SETUP
CLR ALL INT
CLR ALL CART
FORMAT CART
DUMP
COPY SETUP copies a program or register to a  speci-
fied register location
INT  TO  CART  copies  all  the  registers  in  internal
memory to the cartridge
CART TO INT copies all the registers in the cartridge to
internal memory
MOVE SETUP copies a register  to  a specified register
location, and deletes the original.
CLR SETUP deletes the specified register
CLR ALL INT clears all  internal registers
CLR ALL CART clears all registers in the cartridge
FORMAT CART formats the cartridge
DUMP allows MIDI tranmission of Automation data.
To perform any of these functions, hold down STO and
press REG.
SRC (Source)
SRC selects the source register or program for clear-
ing, moves or copies.
DST (Destination)
DST  selects  the  destination  register  for  copies  or
moves.