Справочник Пользователя для Lexicon lexicon480lv4

Скачать
Страница из 150
E-4
Lexicon 480L Owner's Manual
PGM (Program Change Mode)
Pgm determines what the 480L will do with incoming
MIDI program changes. PGM has three options:
IGNORE (Ignore incoming program changes)
FIXED (incoming program changes 0 to 99 are
mapped directly to register numbers; 100 to 127
are mapped to the first 28 programs)
TABLE ( Uses the corresponding register table
created with PGM and TBL)
Page Six
Page Six  contains MIDI SysEx controls.
SFN (SysEx Function)
Determines  the  type  of  bulk  data  dump.  There  are
seven choices:
Setup
Bank
Active
All Internal
All Cartridge
MIDI Map
Control Page Info
SRC (Source)
Selects the SysEx source for the dump. The available
selections  are  determined  by  the  setting  of  Slider  1
(SFN).
RCV (Receiver)
Determines the destination of all SysEx loads.
480L Power-Up State
Normally  if  power  is  lost,  or  turned  off,  and  then
restored, the 480L will return to its last previous state.
You can also configure the 480L to automatically load
pre-selected programs upon power up.  To do this, go
to Control Mode, Page two, slider 5. This slider, labeled
DEF for default, is set at the factory   to “off”.  Advancing
the slider will scroll through all of the 480L programs
and  select  one  as  the  new  default  state.  The  upper
display will indicate the machine you are addressing,
followed by the Bank number, Program number and
Program name.  In order to select a default load for the
second machine, press the MACH button and advance
the slider to the desired program.
Control  configuration  is  always  remembered  re-
gardless of power-up default setting.