Справочник Пользователя для Crestron cnxenet plus

Скачать
Страница из 32
CNX Enhanced Ethernet Expansion Card 
Crestron CNXENET+
 
26-pin male connector attaches to the DPA connector. Items 1 through 3 listed below 
for installation onto the CNXCPU. The only tools required are a grounding strap and 
a #1 Phillips tip screwdriver. 
Referenced Items for CNXCPU Installation 
ITEM
DESCRIPTION
PART NUM BER
QUANTITY
1
Screw, 4-40 x 1/4"L, steel, 
pan, phillips, black
SR04-40-0R2500-11
2
2
Plate, blank, m etal, LAN/DPA M TPL02390-1
1
3
CNXENET+
ZA11281
1
 
CAUTION:  The CNXENET+ and the CNXCPU contain ESD sensitive devices. 
Perform the following procedure while wearing a grounding strap that is properly 
grounded or on a grounded work station to avoid damaging the card and/or the 
CNXCPU.  
1.  Disconnect power from the control system. 
2.  At the CNXCPU, note the position of any attached cables and 
disconnect each cable. 
3.  Loosen the CNXCPU thumb screws and pull outward to remove card. 
4.  Refer to the diagram below. From the CNXCPU faceplate, use a #1 
Phillips tip screwdriver and remove the two mounting screws   that 
secure the LAN/DPA cover plate   and remove the plate. 
CNXCPU Installation (1 of 3) – Remove Screws and Cover Plate 
1
2
 
6  
  CNX Enhanced Ethernet Expansion Card: CNXENET+ 
Operations & Installation Guide – DOC. 8153A