QuickMedia™ Receiver/Processor                             Crestron QM-RMCRX 
RJ-45 Pinouts 
 
Once the cable connections are made, open the Crestron Viewport and click 
Setup | Communication Settings on the menu to display the “Port Settings” 
window. Then click TCP/IP as the connection type. Enter the IP address of the 
QM-RMCRX. 
“Port Settings” Window 
 
To verify communication, click Diagnostics | Establish Communications 
(Find Rack).
 This should display a window that gives the IP address and port 
number. 
NOTE:  To define the setup of DHCP-based Ethernet communication, refer to 
the Crestron e-Control Reference Guide (Doc. 6052). 
NOTE:  When using Viewport/Test Manager via the Ethernet, the default 
Crestron Terminal Port (CTP) is 41795. 
NOTE:  Default Ethernet Ports: 
80 = Web 
41794 = Crestron Com 
41795 = Viewport/Debug 
22 
 QuickMedia™ Receiver/Processor: QM-RMCRX 
Operations Guide - DOC. 6236A