Справочник Пользователя для Crestron qm-rmcrx

Скачать
Страница из 64
Crestron QM-RMCRX  
         QuickMedia™ Receiver/Processor
 
Troubleshooting Communications 
Use the following checklist if communication cannot be established with the 
QM-RMCRX. 
1.  Verify that you are using the correct cables. As described previously, 
an RS-232 connection requires a null modem RS-232 cable with DB9 
female connectors on both ends. TCP/IP connection requires a CAT5 
cable with 8-pin RJ-45 connectors. 
2.  With a serial connection, verify that the correct COM port on the PC 
has been selected. Some computers have more than one COM port; 
some may be internal (e.g., for a modem). Consult the manufacturer’s 
documentation for further information about the COM ports on your 
PC.  
3.  Ensure that you have a serial connection to Port B, and reset the control 
system as follows: 
a.  Open Viewport and click Setup | Communications Settings to 
display the “Port Settings” window. Choose RS-232 as the 
connection type. 
b.  Set the baud rate of the PC to 115200
c.  Set the baud rate of the QM-RMCRX control system to 115200, as 
follows: 
Press and release the HW-R button on the unit’s front panel. 
Press and hold the SW-R button for approximately three to 
five seconds. The Viewport console should display the 
following message:  
 Viewport Message 
QMRMCRX> 
Control Console 
Changing to default Comm Specs. 115200 N81 RTS/CTS 
Switch to new settings…. 
Bypassing Program Load!!!
 
 
- Release 
the 
SW-R button. 
d.  If communication still cannot be established: 
Remove power from the control system.  
Press and hold the SW-R button on the front panel of the QM-
RMCRX. 
Reapply power to the control system.  
The Viewport console should display the message shown 
above.  
- Release 
the 
SW-R button. 
e. Select 
Set Baud Rate on the Viewport Functions menu (or press 
F8) and choose any baud rate from the drop-down list. This will 
attempt to establish a connection at the indicated baud rate. If the 
connection is successful, both the PC and the control system will 
be set to the new baud rate. The QM-RMCRX will return to its 
original communication settings when the program reinitializes. 
Operations Guide – DOC. 6236A 
  QuickMedia™ Receiver/Processor: QM-RMCRX 
 23