Справочник Пользователя для Crestron qm-rmcrx

Скачать
Страница из 64
QuickMedia™ Receiver/Processor                             Crestron QM-RMCRX 
Crosshatch Test Pattern 
 
Examples 
Example projects are available from the Creston FTP site 
(ftp://ftp.crestron.com/Examples). Search for: QM-RMCRX. 
Problem Solving 
Troubleshooting  
The following table provides corrective action for possible trouble situations. If 
further assistance is required, please contact a Crestron customer service 
representative.  
QM-RMCRX Troubleshooting 
TROUBLE 
POSSIBLE 
CAUSE(S) 
CORRECTIVE ACTION 
PWR LED 
does not 
illuminate. 
Control system is not 
receiving power. 
Verify that the DC output plug is properly 
attached to the control system and that 
the adaptor is securely plugged into an 
outlet. Use only Crestron power supplies 
for Crestron equipment. 
Compilation 
Error 
RLCMCVT166 

RLCMCVT177 
Poor analog versus serial 
signal definition in the 
SIMPL Windows program. 
Confirm properly defined signal 
definition in the program. 
System locks 
up. 
Various. 
Press and release HW-R button then 
hold SW-R to bypass the program.   
Also refer to “Troubleshooting 
Communications” on page 23. 
Various. 
Refer to the “System Monitor” procedure 
following this table. 
System does 
not function. 
Incorrect power supply. 
Use a Crestron power supply. 
Troubleshooting continued on following page 
32 
 QuickMedia™ Receiver/Processor: QM-RMCRX 
Operations Guide - DOC. 6236A