Справочник Пользователя для Bay Technical Associates BayTech DS72

Скачать
Страница из 38
DS72 Host Module 
 
13
Detailed Operation and Configuration 
Main Screen 
DS72 - Ethernet & RS232 Host module for DS SERIES chassis 
Once connected, you will see the menu screen as shown below. This shows the operation of the unit. 
Depending on which Network Host module you have, the below screens may vary.  The screens below 
are show with the DS72 module.  When prompted at the unit’s startup menu select “C” followed by a 
<cr>. This will take you to the Configuration menu. 
 
 
 
NOTE: Only the Admin user will see the Configuration, Unit Reset, and I/O Module Reset 
options. All users will see only the ports assigned to them, alone with ‘Exit’ and ‘Logout’. 
 
NOTE: 
If you get the following message after selecting the ‘Configure’ option, the other port 
has the configuration option selected. 
 
 
 
IMPORTANCE: Once you make a change to any of the Configuration options, you have to 
back out of the Configuration menu and will be asked to ‘Accept’ changes. If you type ‘y’ for 
yes and press <cr>, the changes take effect immediately for the serial port. For the Ethernet port 
you must do a Unit Reset to get the changes to take effect. 
  
 
 
Accept changes ? (Y/N) :y 
Changes accepted. 
    Module: 2 
Attention Character: ;    
Device A        ................1    
Device B        ................2    
Device C        ................3    
Device D        ................4    
DS-RPC          ................5 
Status of outlets 
Configure.......................C Module 
Setup 
Status..........................S 
Current Setup Configuration 
Unit Reset......................RU  Resets the DS-Unit, terminates internal, 
      external 
modem 
connections, 
allow 
10 
 
      seconds 
for 
reset. 
Logout..........................T 
Configuration mode in use.