Справочник Пользователя для Bay Technical Associates BayTech DS72
DS72 Host Module
13
Detailed Operation and Configuration
Main Screen
Main Screen
DS72 - Ethernet & RS232 Host module for DS SERIES chassis
Once connected, you will see the menu screen as shown below. This shows the operation of the unit.
Depending on which Network Host module you have, the below screens may vary. The screens below
are show with the DS72 module. When prompted at the unit’s startup menu select “C” followed by a
<cr>. This will take you to the Configuration menu.
Once connected, you will see the menu screen as shown below. This shows the operation of the unit.
Depending on which Network Host module you have, the below screens may vary. The screens below
are show with the DS72 module. When prompted at the unit’s startup menu select “C” followed by a
<cr>. This will take you to the Configuration menu.
NOTE: Only the Admin user will see the Configuration, Unit Reset, and I/O Module Reset
options. All users will see only the ports assigned to them, alone with ‘Exit’ and ‘Logout’.
NOTE: If you get the following message after selecting the ‘Configure’ option, the other port
has the configuration option selected.
options. All users will see only the ports assigned to them, alone with ‘Exit’ and ‘Logout’.
NOTE: If you get the following message after selecting the ‘Configure’ option, the other port
has the configuration option selected.
IMPORTANCE: Once you make a change to any of the Configuration options, you have to
back out of the Configuration menu and will be asked to ‘Accept’ changes. If you type ‘y’ for
yes and press <cr>, the changes take effect immediately for the serial port. For the Ethernet port
you must do a Unit Reset to get the changes to take effect.
back out of the Configuration menu and will be asked to ‘Accept’ changes. If you type ‘y’ for
yes and press <cr>, the changes take effect immediately for the serial port. For the Ethernet port
you must do a Unit Reset to get the changes to take effect.
Accept changes ? (Y/N) :y
Changes accepted.
Changes accepted.
Module: 2
Attention Character: ;
Device A ................1
Device B ................2
Device C ................3
Device D ................4
DS-RPC ................5
Attention Character: ;
Device A ................1
Device B ................2
Device C ................3
Device D ................4
DS-RPC ................5
Status of outlets
Configure.......................C Module
Setup
Status..........................S
Current Setup Configuration
Unit Reset......................RU Resets the DS-Unit, terminates internal,
external
external
modem
connections,
allow
10
seconds
for
reset.
Logout..........................T
Configuration mode in use.