Change serial numbers. 
• 
Run scripts to automate tasks. 
• 
Perform system diagnostics, and much more. 
The Crestron Toolbox allows you to perform these functions using simple 
graphical views and click and drag methods. 
Identity Code 
Every piece of equipment and user interface within the network requires a 
unique identity code (Net ID). These codes are two-digit hexadecimal numbers 
from 03 to FE (Net ID 02 is reserved for master control units). The Net IDs 
reside within all Cresnet devices (hardware) and must match the Net ID as 
specified in the software (SIMPL Windows) that runs the system. Refer to 
“Setting the Net ID in Device Settings” on page 33 for details of the SIMPL 
Windows procedure.  
The Net ID of the QM-FTMC has been factory set to 0A. The Net IDs of 
multiple QM-FTMCs in the same system must be unique. Net IDs can be 
changed from a personal computer (PC) using SystemBuilder
 or Crestron 
Toolbox. 
NOTE: For detailed information on establishing communication between the 
PC and control system, refer to “Communication Settings” on page 46. If 
communication cannot be established, refer to the “Troubleshooting 
Communications” section in the latest version of the 2-Series Control System 
Reference Guide (Doc. 6256), which is available from the Crestron website 
(http://www.crestron.com/manuals). 
The Crestron Toolbox provides several methods to easily set or change device 
Net IDs for any device on the network. The following method permits you to 
change the Net ID of any device in the network through the “Network Device 
Tree” window.  
NOTE: This method prevents you from setting duplicate IDs. 
This method permits you to manually set the Net ID for any device in the 
network, can be used to set any known Net IDs that may require changing, and 
may also be used for non-TSID equipment. This method will not permit you to 
choose an ID already in use by another device. A warning message will appear 
if you attempt to use an ID that is already in use. 
Duplicate Net ID Warning Message 
 
This method does not change the Net ID as assigned in SIMPL windows. Refer 
to page 33 for the SIMPL Windows ID change procedure. 
NOTE: You may also use SystemBuilder to perform Network ID setup. Refer 
to page 30 for Net ID setup details using SystemBuilder. 
16 
 FlipTop Media Center: QM-FTMC 
 
Operations & Installation Guide - DOC. 6311A