Crestron CLT- & CLX-1FAN4   
Terminal Block & Module 
Module Installation 
CAUTION:  Module contains electrostatic sensitive 
devices (ESDs); unit must be handled from metal 
chassis – do not touch PC board or components. 
NOTE:  Modules are to be installed after enclosure 
has been completely wired. Refer to the terminal 
block installation procedure on page 2 for details.  
1.  Use the four supplied self-tapping pan Phillips 
screws (8B x ¼ length) to secure the module to 
the enclosure.  
2.  As shown in the wiring diagrams (next column), 
connect the wires from the module to the 
terminal block. Each wire exits the module 
directly in line with, and is the same color as, the 
terminal to which it should be connected. Wires 
are pre-stripped to ½ inch. Tighten to 9 in-lbs. 
Do not over tighten.  
3.  If the module is being installed above another 
module within the enclosure, attach the supplied 
module interconnect cable between the two 
modules. The illustration below depicts the area 
within a double-wide enclosure where the 
corners of four modules meet.  
NOTE:  One wire on the module interconnect cable 
may be a different color from the rest. The color has 
no bearing on its orientation during installation.  
Use Module Interconnect Cable to Wire Module to Module  
           
MODULE
 
INTERCONNECT
 
CABLE ATTACHED
 
CONNECTION
NOT
MADE
 
4.  Turn on the circuit breaker and verify that the 
green PWR LED on the module lights and that 
the breaker does not trip.  
NOTE: Each fan that is to be controlled must be set 
to full speed. Refer to the fan’s instruction manual for 
instructions on setting the fan to full speed. 
NOTE: If a light is included with the fan, it must be 
wired to a separate lighting control module (e.g. 
CLX-1DIM4). The CLX-1FAN4 cannot be used to 
control lights. If the light and fan share a single 
neutral wire, the wire should be connected to the 
dimmer module. 
Wiring Diagram of the Terminal Block to the Module 
(Single-wide and Left Side Double-wide Enclosures) 
ATTACH MODULE
INTERCONNECT CABLE
(DESCRIBED IN STEP 3)
WHITE
BLACK
RED
 
Wiring Diagram of the Terminal Block to the Module 
(Right Side Double-wide Enclosures) 
ATTACH MODULE
INTERCONNECT CABLE
(DESCRIBED IN STEP 3)
WHITE
BLACK
RED
 
5.  If the program is not running yet, loads can be 
tested by using Local Mode. 
 
Use Local Mode to verify that each load is connected to 
the proper output on the modules.  
1. Press 
the 
SETUP button momentarily (less than 
three seconds) to enter Local Mode. 
The SETUP LED and output LED 1 illuminate 
and power is applied to the device connected to 
output for 1 second.  
2. Press 
the 
SETUP button again to pulse output 2.  
3.  Repeat step 2 for each output. 
4. Press 
the 
SETUP button once more to turn off 
all outputs and LEDs and exit the Local Mode.  
Installation Guide – DOC. 6032A 
Terminal Block & Module:  CLT- & CLX-1FAN4  
  3