Preventive and Corrective Maintenance
Printed Circuit Boards—DC Motor Maintenance
Figure 157 • Ribbon Supply/Take-Up DC Motor Installation/Removal
4.
. Loosen and remove the two 2.5 mm mounting screws for either the ribbon 
take-up or the ribbon supply motor.
Figure 158 • Ribbon Supply/Take-Up Motor
5.
. Remove the motor and gear through the access hole on the 
bracket.
6.
. Gently remove the wire leads from the motor and make note which lead is 
connected the positive (+) terminal.
Important • 
Depending on the type of print engine you are working on, left-hand or right-
hand, the ribbon take-up is slightly higher than the ribbon supply. 
Ribbon Supply
Motor
Ribbon Take-Up
Motor
Spacers
Motor Bracket
Access Hole
Access Hole
Wire Leads 
with Two 
Black Wires