Справочник Пользователя для Zebra 49834
282
170PAX4 Maintenance Manual
57518L-001 Rev. A
3/18/05
Preventive and Corrective Maintenance
Printed Circuit Boards—DC Motor Maintenance
Figure 157 • Ribbon Supply/Take-Up DC Motor Installation/Removal
4.
. Loosen and remove the two 2.5 mm mounting screws for either the ribbon
take-up or the ribbon supply motor.
Figure 158 • Ribbon Supply/Take-Up Motor
5.
. Remove the motor and gear through the access hole on the
bracket.
6.
. Gently remove the wire leads from the motor and make note which lead is
connected the positive (+) terminal.
Important •
Depending on the type of print engine you are working on, left-hand or right-
hand, the ribbon take-up is slightly higher than the ribbon supply.
Ribbon Supply
Motor
Ribbon Take-Up
Motor
Spacers
Motor Bracket
Access Hole
Access Hole
Wire Leads
with Two
Black Wires