Other electrical devices, 
such as computers, 
televisions or power strips, 
may be absorbing the 
INSTEON signal 
On/Off Module is taking a long time 
to respond to a controller  
The controller may be 
sending commands to a 
responder that is no 
longer in use. Commands 
for the unused responder 
are being resent and 
slowing down the network 
Remove from the scene any unused 
responders from the controller. (HINT: 
If you are using home automation 
software, you can easily check scene 
membership and eliminate 
unnecessary memberships.) 
If the above doesn’t work, perform a 
factory reset on the controller 
Responders are taking a long time 
to respond to On/Off Module 
On/Off Module may be 
sending commands to a 
responder that is no 
longer in use. Commands 
for the unused responder 
are being resent and 
slowing down the network 
Remove from a scene any unused 
responders from On/Off Module. 
(HINT: If you are using home 
automation software, you can easily 
check scene membership and 
eliminate unnecessary responders.) 
If the above doesn’t work, perform a 
factory reset on On/Off Module. See 
. 
The load turned on by itself 
Another controller, a timer 
or stray X10 signals could 
have triggered On/Off 
Module 
Perform a factory reset on On/Off 
Module. See 
. 
On/Off Module can turn off a 
responder, but nothing happens 
when I send an on command from 
On/Off Module 
The responder may be 
added to the scene at its 
off state 
Add the device to a scene as a 
responder to On/Off Module, while the 
responder’s load is on. See the 
responder’s Owner’s Manual for more 
detailed scene adding instructions. 
The controller can turn off On/Off 
Module, but On/Off Module does 
not turn on when I send an on 
command from the controller 
On/Off Module may be 
added to a scene at its off 
state  
Re-add On/Off Module to a scene as 
a controller while the load is on. See 
. 
On/Off Module is locked up 
A surge or excessive 
noise on the powerline 
may have locked it up 
Unplug On/Off Module for 10 seconds 
and then reinstall 
If the above doesn’t work, perform a 
factory reset. See 
The load does not turn on when I 
manually activate the load’s built-in 
switch 
On/Off Module may be off 
Turn on On/Off Module using the 
paddle on the side of the module 
Bulb may be burnt out 
Replace the lamp’s bulb 
The load is not being controlled by 
On/Off Module 
The load may not be 
getting power 
Make sure the load’s built-in switch is 
in the on position 
 
Phase Bridge Detect Beacon/RF Range Test 
Dimmer module automatically bridges the electrical phases in your home (via communications with other 
dual-band devices on the “other phase”). This is only important in 2-phase homes with powerline-only