Справочник Пользователя для INSTEON 2633-442 (uk)

Скачать
Страница из 14
 
Page 13 of 14                                                                                                             Rev: 1/21/2014 7:47 AM
 
 
INSTEON products or buildings with both 2- and 3- phase circuits. The phase bridge detect beacon can 
also be used as an RF range test to see if your devices are within communication range. You will need at 
least one other INSTEON dual-band device installed. 
 
1)  Press and hold set button until it beeps 
 
 
LED will start blinking green  
2)  Press and hold set button until it beeps a second time 
 
 
LED will start blinking red
 
3)  Press and hold set button until it beeps a third time 
 
 
LED will start blinking green
 
4)  Slowly tap set button 2 times 
LED will continue blinking green
 
5)  Press and hold set button until it beeps 
Micro module will start beeping once per second 
LED will turn solid green
 
6)  Check the LED behavior of other dual-band devices 
 
Phase Bridge Detect Beacon 
• 
If the other dual-band device is blinking
 
green, it is on the other phase:
 
Device provides a phase bridge to Dimmer module 
• 
If the other dual-band device is blinking red, it is on the same phase: 
Device does not provide a phase bridge to Dimmer module 
Relocate if necessary (and practical)
 
• 
If the other dual-band device is not blinking:
 
Device is not within RF range of Dimmer module so it does not provide a phase bridge 
Relocate if necessary (and practical) or add an additional dual-band device 
 
RF Range Test 
• 
If LED is blinking:
 
Device is within RF communication range 
• 
If LED is not blinking:
 
Device is not within RF communication range 
Relocate if necessary (and practical) or add an additional dual-band device 
7)  Tap set button 
Dimmer module will stop beeping 
 
Other device LEDs will stop blinking 
 
 
If you have tried these solutions, reviewed the owner's manual, and still cannot resolve an issue, visit 
 or call INSTEON Support Line at 866-243-8022. 
 
Certification and Warranty 
DECLARATION OF CONFORMITY  
 
Hereby, INSTEON declares that this device is in compliance with the essential requirements and other relevant provisions of the following Directives: 
 
1) Low Voltage Equipment Directive 2006/95/EC 
2) Electromagnetic Compatibility Directive 2004/108/EC 
3) Hazardous Substance Directive 2005/95/EC 
 
Technical data and copies of the original Declaration of Conformity are available and can be obtained from INSTEON; 16542 Millikan Ave, Irvine, CA, 
USA. 
 
 
User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE) 
 
This document contains important  information for users with regards to the proper disposal and recycling of INSTEON products. Consumers are 
required to comply with this notice for all electronic products bearing the following symbol: 
 
Environmental Information for Customers in the European Union