Programming Model
Page 79 of 377
2.1.4.2 Thermal-Management Register 3 (THRM3)
The THRM3 register is used to enable the thermal assist unit and to control the timing of the output sample 
comparison. The thermal assist logic manages the thermal-management interrupt generation and time-multi-
plexed comparisons in dual-threshold mode, as well as other control functions.
The THRM registers can be accessed with the mtspr and mfspr instructions using the following SPR 
numbers:
• THRM1 is SPR 1020
• THRM2 is SPR 1021
• THRM3 is SPR 1022
Table 2-3. Valid THRM1/THRM2 Bit Settings 
TIN
TIV
TID
TIE
V
Description
x
x
x
x
0
Invalid  entry.  The  threshold  in  the  SPR  is  not  used  for  comparison.
x
x
x
0
1
Disable thermal-management interrupt assertion.
x
x
0
x
1
Set TIN and assert thermal-management interrupt if TIE = 1 and the junction temper-
ature exceeds the threshold. If TIE = 0, then no interrupt will be taken when the 
threshold is achieved.
x
x
1
x
1
Set TIN and assert thermal-management interrupt if TIE = 1 and the junction temper-
ature is less than the threshold.
x
0
x
x
1
The state of the TIN bit is not valid.
0
1
0
x
1
The junction temperature is less than the threshold and as a result the thermal-man-
agement interrupt is not generated for TIE = 1.
1
1
0
x
1
The junction temperature is greater than the threshold and as a result the thermal-
management interrupt is generated if TIE = 1.
0
1
1
x
1
The junction temperature is greater than the threshold and as a result the thermal-
management interrupt is not generated for TIE = 1.
1
1
1
x
1
The junction temperature is less than the threshold and as a result the thermal-man-
agement interrupt is generated if TIE = 1
1. TIN and TIV are read-only status bits.
Reserved
SITV
E
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Bits
Field Name
Description
0:14
Reserved
Reserved for future use. System software should clear these bits when writing to THRM3. 
15:30
SITV
Sample interval timer value. Number of elapsed processor clock cycles before a junction 
temperature versus threshold comparison result is sampled to set the TIN bit and gener-
ate an interrupt. This is necessary due to the thermal sensor, the digital-to-analog con-
verter (DAC), and because the analog comparator settling time is greater than the 
processor cycle time. The value should be configured to allow a sampling interval of 20 
microseconds.
31