Crestron QM-RMC  
 
 
Room Media Controller
 
acceptable; they should have at least five pins for transmit, receive, ground, and 
hardware handshaking (pins 2, 3, 5, 7 and 8).  
Serial console connection may be established only if SW-R button is pressed 
and held during power up, or if pressed and held at the same time HW-R is 
momentarily pressed.  
NOTE:  The Viewport utility performs multiple system tasks, primarily via an 
RS-232 or TCP/IP connection between the control system and a PC. It is used to 
observe system processes, upload new operating systems and firmware, change 
system and network parameters, and communicate with network device consoles 
and touchpanels, among many other tasks. Viewport can also function as a 
terminal emulator for generic file transfer. All of these functions are accessed 
through the commands and options in the Viewport menus. Viewport is 
available through the SIMPL Windows and Crestron VisionTools
®
 (VT Pro-e) 
software. 
Open the Crestron Viewport and click Setup | Communication Settings to 
display the “Port Settings” window. Then click RS-232 as the connection type. 
NOTE:  Changes in communication settings are not saved after the QM-RMC is 
rebooted. It reverts to default settings. 
The PC communication settings specified here should match the protocol that 
the QM-RMC expects. The settings are as follows: 
•  Port = COM 1 through COM 8. Select the correct COM port on the PC. 
•  Baud rate = 115200 (You can set the PC and the control system to a 
different baud rate, by using the Functions | Set Baud Rate command. 
•  Parity = None. 
•  Number of data bits = 8. 
•  Number of stop bits = 1. 
•  Hardware handshaking (RTS/CTS) enabled. 
•  Software handshaking (XON/XOFF) not enabled. 
Operations Guide – DOC. 6161 
 
Room Media Processor: QM-RMC 
 11