Справочник Пользователя для Crestron qm-rmc

Скачать
Страница из 36
Room Media Controller 
 
 
Crestron QM-RMC 
“Port Settings” Window: 
Default PC Settings for RS-232 Communication with the QM-RMC 
 
To verify communication, click Diagnostics | Establish Communications 
(Find Rack)
. This should display a window that gives the COM port and baud 
rate. 
TCP/IP Connection 
Before you can communicate with the QM-RMC over TCP/IP, you must use the 
RS-232 connection just described to configure the unit’s TCP/IP settings. Obtain 
the static address from the network administrator. 
1.  Open Viewport and click Functions | Set Control System IP 
Information
2.  Enter the IP address, IP mask and default router in the text fields. All of 
these terms are explained in detail in the Crestron e-Control Reference 
Guide, Doc. 6052. The latest version is available as a PDF on the 
Crestron website (www.crestron.com). 
3.  Click OK to set the new IP information. 
Once you have assigned the IP settings, you can continue to communicate with 
the QM-RMC using the RS-232 connection, or you can establish a TCP/IP 
connection.  
For TCP/IP, use CAT5 straight through cables with 8-pin RJ-45 connectors to 
connect the LAN port on the QM-RMC and the LAN port on the PC to the 
Ethernet hub. Alternatively, you can use a CAT5 crossover cable to connect the 
two LAN ports directly, without using a hub. The following figure illustrates 
pinouts for straight through and crossover RJ-45 cables. Pins 4, 5, 7, and 8 are 
not used. 
12 
 Room Media Processor: QM-RMC 
 
Operations Guide - DOC. 6161