Справочник Пользователя для Crestron qm-rmc

Скачать
Страница из 36
Crestron QM-RMC  
 
 
Room Media Controller
 
to reach all devices. It is designed to handle multiple IR codes so that only one 
sprayer is needed for many devices. 
NOTE:  The C2I-IR1 port does not support simultaneous IR and RS-232 
control. That is, an IR driver cannot be stacked on the port together with a one-
way serial driver. The control format must be of one type. Use only one 1-way 
Serial Driver or up to five IR drivers. 
In addition, the IR port does not have negative voltage and thus may not provide 
the full voltage range required by some RS-232 devices (although nearly all RS-
232 devices will operate properly). In these cases the DB9 serial COM ports can 
be used instead. 
Slot 2: C2I-DI04 
Slot 2 provides four digital input ports: <o1> through <o4
 
Signals 
•  Digitals: <o1> through <o4> 
Description 
The C2I-DIO4 provides four digital inputs for connection of external sensors or 
other contact closure devices. The <o> outputs are a logical high until it detects 
the presence of a low on the corresponding input. 
The built-in port supports dry contact closure to ground. 
Slot 3: C2I-COM2-232 - Port A and Port B 
The C2I-COM2-232 provides two COM ports (A and B) for controlling serial 
devices over RS-232.  
NOTE: Does not support RS-422 or RS-485. 
Each COM port has a built-in two-way serial driver.  
To program a serial driver or serial device expand the C2I-COM-2 in Program 
View
 and drag the item to Detail View
 
Operations Guide – DOC. 6161 
 
Room Media Processor: QM-RMC 
 21