Signals 
•  Serial input for one-way and two-way serial drivers: <tx$> (transmit) 
•  Serial output for two-way serial drivers: <rx$> (receive) 
•  Digital inputs for two-way serial drivers: <rts> (request to send), <dtr
(data terminal ready), <in1> through <in2000> and <break
•  Digital output for two-way serial drivers: <cts> (clear to send), 
<RingIn> (ring indicator), <CarrierDetect>, <dsr> (data set ready). 
•  Digital input: <enable
•  Parameters: <str1>, <str2>, <delimiter
The <tx$> (transmit) and <rx$> (receive) signals send and receive serial strings 
using whichever communication format, or protocol, the serial device requires. 
This protocol is usually described in the manufacturer's documentation and 
includes the transmission speed (baud rate), error checking (parity), number of 
data bits and stop bits, and any hardware or software handshaking that may be 
required to control the flow of data. 
Slot 4: C2ENET-1 
The C2ENET-1 network interface card provides one LAN port with an RJ-45 
connector for connecting the QM-RMC to the Ethernet network.  
The card provides 252 IP IDs for Ethernet devices. 
To facilitate network functions and diagnostics, SIMPL Windows provides one 
device extender for the C2ENET-1 card: Device Status. 
To add the device extender, right-click the C2ENET-1 card in Program View
point to Insert Device Extender and click Device Status
To program an Ethernet device or device extender, expand the C2ENET-1 card 
in Program View and drag the item to Detail View