Справочник Пользователя для Infinet Malta Limited LM-5X18

Скачать
Страница из 88
InfiNet Wireless R5000 
 
Technical User Manual 
 
Copyright © 2004-2010 by InfiNet Wireless 
58 
 
Indicator panel: 
 
 
How to use: 
Turning on: 
1. For turning InfiNet Wireless RapidView-1 on simply push «Power button». 
2. Device LEDs will light up for 2 seconds.  
3. Device will perform constant tries to connect to ODU. If device‘s power is 
normal  Power/ODU  connection  LED  (1)  will  blink  1  time  per  second.  If 
device‘s power is low LED 1 will blink 4 times per second in turn with not 
lighting intervals.  
4. Once ODU link is established LED 1 stops blinking (if power is normal) and 
device‘s interfaces status are shown by LEDs 2-6. 
5. 1 time per second device updates its status output. 
6. If ODU link will be broken LEDs 2-6 will go out after 2 seconds and LED 1 
will start blinking 1 time per second. 
Diagnostic  device  connection  to  ODU  should  be  done  via  console  port  of  the 
ODU. Once link is up between ODU and diagnostic device the following record is 
put in ODU system log:  
Connected test unit. Begin service communication over console. 
Test unit detected: rf0 – rf4.0
 
Exact radio interface names depend on wireless equipment configuration. 
When  diagnostic  device  is  unplugged  from  the  following  record  is  put  in  ODU 
system log:  
Test unit disconnected. Return to normal console mode. 
 
LEDs modes description: 
ODU status monitoring via diagnostic device is performed by its LEDs indication. 
LEDs modes and ODU status correspondence is shown in the following table: