Справочник Пользователя для Infinet Malta Limited LM-5X18

Скачать
Страница из 88
InfiNet Wireless R5000 
 
Technical User Manual 
 
Copyright © 2004-2010 by InfiNet Wireless 
59 
 
LEDs 
Function 
1. Power/ODU 
connection LED 
Shows diagnostic device power status and diagnostic device-ODU connection status. 
 
Constant lighting — diagnostic device-ODU connection established, diagnostic device power is 
normal. 
Blinking 1 time per second — diagnostic device power is normal, diagnostic device-ODU 
connection is not established. 
Blinking 4 times per second — diagnostic device-ODU connection established, diagnostic 
device power is low (change batteries). 
Frequent blinking with intervals — diagnostic device power is low, diagnostic device-ODU 
connection is not established. 
2. Radio link LEDs 
Show whether radio link is established on certain ODU‘s radio interface.  
 
Constant lighting — radio link is established.  
 
What ODU‘s radio interface to show by what column RF0 or RF1 is chosen by the following 
way:  
for RF0 column is taken radio interface with the least number, for RF1 the other interface.  
For example, there are the following radio interfaces on ODU: 
rf4.0, rf5.0. Then for RF0 column rf4.0 will be taken, for RF1 — rf5.0. 
 
When no radio link then LEDs 2-4 are not lighting. 
3. Radio signal 
overload/Packets 
retries LEDs 
Show receiving radio signal level overload and number of packet retries information. 
 
Constant lighting —receiving radio signal level on the interface is too high. 
Blinking 4 times per second -  number of retries >= 50% 
Blinking 2 times per second -  number of retries >= 28 % 
Blinking 1 time per second -  number of retries >= 7 % 
 
If certain radio interface (radio module) is not present on the device then all corresponding 
LEDs of this radio interface is off. 
If ODU has certain radio interface but it is not activated (for example, not entered «mint rf4.0 
start» command) then LED 3 is blinking 1 time per second whereas LEDs 2 and 4 are not 
lighting. 
If ODU has certain radio interface but it is not activated (for example, not entered «mint rf4.0 
start» command) then LED 3 is blinking 1 time per second whereas LEDs 2 and 4 are not 
lighting. 
If ODU has certain radio interface activated («mint rf4.0 start» command entered) then LED 3 
is blinking 4 times per second whereas LEDs 2 and 4 are not lighting. 
4. Radio signal level 
scales 
Show receiving signal level of the established radio link.  
 
Each LED can be in 4 modes: 
Not lighting — radio signal level is lower than scale value. 
Blinking — the more frequently is blinking the nearer signal level is to given scale value. 
Constant lighting — signal level is higher or equal to scale value. 
5. Ethernet interface 
speed LEDs  
Show speed of corresponding Ethernet interface. 
 
There are 2 LEDs for each Ethernet interface (Eth0 and Eth1). 
 
10 Mbps 
100 Mbps 
1000 Mbps 
Error 
Upper LED 
Lighting 
Not lighting 
Lighting 
Blinking 
Lower LED 
Not lighting 
Lighting 
Lighting 
Blinking 
 
6. Ethernet interface 
mode LEDs 
Constant lighting — Full Duplex. 
Not lighting — Half Duplex. 
 
IF Ethernet connection is established but corresponding ODU‘s interface is not enabled then 
LEDs 5, 6 indicate connection configuration by blinking 1 time per second.