Section 5 -  Installing Hardware 
 
33 
wSIMs  and  Repeaters  are  designed  for  Zone  0 
hazardous  area  approvals.  Check  with  your  Bently 
Nevada  representative  to  find  out  which  approvals 
are available for your region. 
5.3.1  Choosing a Mounting Location 
Mount the wSIMs in locations such that: 
 
The  field  wiring  can  be  routed  between  the 
transducers and the wSIMs. 
 
The  wSIM  is  installed  such  that  there  are  3 
other  nodes  within  a  50M  to  75M  radius 
around the node.  This will ensure the wSIM 
will  have  multiple  paths  to  communicate  to 
resulting in highly reliable communications. 
The  mounting  location  for  wSIMs  requires  a  metal 
surface for the magnet mount option or an adequate 
substrate for drilling and taping a 12.7-mm (0.5-inch) 
hole  to  permanently  mount  the  hex  base  mount.  
Only  use  the  magnet  mount  on  a  ferrous  metal 
surface. 
The wSIM must be mounted such that the cable can 
be  safely  routed  and  secured  to  the  point  the 
transducer  is  mounted.  The  available  cable  lengths 
for  the  accelerometer  and K-type thermocouple  are 
2  m,  4  m,  and  6  m.    There  are  also  optional 
Trendmaster  cables  that  can  be  used  with  the 
accelerometers.  The  15  m  (49ft)  cable  (P/N  200152-
15),  and  25m  (82  ft)  cable  (P/N  200152-25)  must  be 
used  with  field  termination  connector  (P/N  162438-
01).