Operation 
 
 
EverGuard Express 
 
53 
 
 
Figure 28: Control Panel Screen 
2.  To edit a specific parameter, mark the relevant checkbox. The parameter is 
then enabled and you can modify it. 
3.  Under Timer Delay, parameters enable you are able configure the system 
behavior when an entry/exit timed device is triggered. The following Timer 
Delay parameters can be set for: 
  Full Entry Timer 
  Full Exit Timer 
  Part Arm Entry Timer 
  Part Arm Exit Timer 
The valid range for each of these parameters is 1 to 180 seconds. 
4.  Under Sound, set the sound levels and functions of the alarm for the 
following parameters: 
  Beep Level - The beep level controls the volume of the beep and can be 
set from 1 to 7. 
  Internal Siren Sound Level – The internal siren sound level controls the 
volume of the internal siren and can be set from 1 to 9, for Progressive 
(beginning at a lower decibel and escalating) or it can be set to silent. 
  Silent Panic – When Silent Panic is enabled, no siren is heard when the 
operation is activated. 
  Internal Siren Duration – Determines the duration that the internal 
siren sounds. The Internal Siren duration can be set between 5 to 180 
seconds. 
5.  Under Power, set the indicators that notify the monitoring station of power