Справочник Пользователя для Essence Security International ltd. ES6500EGE
Operation
54
EverGuard Express
failure for the following parameters:
220v fail message– Enables or disables the random time message that
is sent to the monitoring station.
220v message delay timeout – Defines the fixed time (in minutes)
message to be sent. If there a power failure, the message is sent
according to this parameter only if the random time is set to zero.
according to this parameter only if the random time is set to zero.
Range limit for 220v fail Random - Sets the time in minutes during
which the message is sent. This parameter can only be configured if the
220V fail message parameter is enabled. It is recommended to set this
parameter for the same value as is set for 220v fail indication plus an
additional 5 minutes.
220V fail message parameter is enabled. It is recommended to set this
parameter for the same value as is set for 220v fail indication plus an
additional 5 minutes.
6. For Active Output Device, for each of the parameters:
ALARM
PANIC
ARM
DISARM
DURESS
From the Device dropdown list, select one of the following:
X-10 devices - can handle stronger appliances (e.g., washing machine,
TV, etc.)
RF Output devices - generally lights, sprinklers, garage door.
Each device must be assigned an ID number.
The range is from 1 to 16.
7. Under Password, configure the following codes:
Duress Pin-Code – Enter a 4 digit code to trigger sending a duress
message to the control center.
CMS DTMF Code – Enter a 4 digit code to activate commands remotely.
8. System Time parameters are read-only and are drawn from the system.
Set the Periodic Test Period, in days, hours, minutes. This is how often the
system should send a test message to the control center.
system should send a test message to the control center.
9. Set the Transmitter parameters according to requirements:
GSM Module – Enables or disables the GSM module.
GSM Ringtones – defines the ringtone when voice call is received by the
control panel. Value available are default plus 1-18.
SIM Pin-Code - Enables or disables the SIM pin code. When using SIM
cards that are unlocked and do not require a PIN code, the SIM Pin-Code
parameter should be disabled.
parameter should be disabled.
SIM Center – Enables or disables the SIM center, which is the cellular
service provider center for sending text messages.
GSM SIM Center Phone Number – Defines the SIM Center telephone
number. To add a GSM SIM Center Phone Number, the SIM Center
parameter must be enabled.
parameter must be enabled.