Section 3 : Installation Procedure
2015_2000007248-V1 - Draft
This document and the information therein are the property of Morpho. They must not be
copied or communicated to a third party without the prior written authorization of Morpho
26
June 2015
Installation
Required tools (not supplied)
Two (2) raw plugs + Two (2) ø 4mm max and length 30mm screws.
One (1) screwdriver adapted to screws above.
One (1) Drill (with a drill bit diameter adapted to raw plugs above).
One (1) hole saw (depending on installation case).
A (1) Torx T10 screwdriver
Deadbolt/door strike
Snubber diode required to protect regulated DC power supply from inductive
kickback (1N4007 diode or equivalent recommended)
kickback (1N4007 diode or equivalent recommended)
Separate power supply for the deadbolt/door strike based on supplier's
recommendations.
recommendations.
External relay (if required)
Networking cable
For UL-294 compliance, an earthed screen in the wire or around all wires to/from
product is only required when the wires share space/compartment/tube with high
voltage cables.
product is only required when the wires share space/compartment/tube with high
voltage cables.
Equipment from the initial package to use
One (1) Terminal’s body,
One (1) pre-wired back door,
One (1) wall plate,
One (1) Protection accessory (optional) to insert over the biometric sensor