Section 3 : Installation Procedure 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
28 
June 2015 
 
 
If  not  present,  drill  in  the  wall  a  hole  with  a  diameter  adapted  to  the  width  of  the 
terminal and the cable to be hosted in (see Figure 7: Drilling template. This template 
at scale 1:1 can be found in the Quick Installation Guide). 
Confirm  the  presence  inside  the  hole  of  all  the  cables  needed  for  the  electrical 
installation (see Electrical Interface) 
Drill in the wall 2 holes with a diameter adapted to screws and fit them with the raw 
plugs (see Figure 7: Drilling template).  
 
Fixing 
 
Be  sure  that  a  sufficient  space  is  reserved  in  the  wall  for  the  passage  of 
cables,  in  particular  for  Ethernet  cable  and  plug,  and  also  for  the  Wi-Fi 
dongle (if applicable). 
 
Figure 8: Wall plate fixing 
Place the wall plate against the wall, opposite the four holes pierced in the wall (see 
Figure 8: Wall plate fixing). 
Cabling 
Cable for wiring shall be AWG 20 to 24, length shall be adapted to the size of the hole 
in  the  wall, to  terminal connections,  and  to  the  distant  between  the  electric  source 
and the terminal itself. 
Closing 
Power has to be set up just after closing it. If product has to be stored for a long time 
(more than 48 hours), don’t forget to restore its configuration before use. 
Finally, lock the product with the screw at the bottom of the terminal. 
 
!