Справочник Пользователя для IDEMIA Identity & Security France MPHAC001A

Скачать
Страница из 74
 
Section 4 : Electrical Interface 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
36 
June 2015 
 
 
Wiegand output wiring 
The following figure  shows  how  to  cable  the  wires  of the  Wiegand  OUT port  of  the 
terminal  for  Wiegand  protocol.  This  is  used,  for  instance,  to  connect  the 
MorphoAccess® SIGMA Lite terminal to an Access Control Panel (ACP). 
  
Figure 15: Wiegand output wiring 
14  Green 
WIEGAND _OUT0 
Out  Wiegand OUT D0 (5V TTL) 
16  White 
WIEGAND _OUT1 
Out  Wiegand OUT D1 (5V TTL) 
17  Blue 
WIEGAND_LEDOUT1 
In 
Wiegand LED IN 1 (option): panel 
feedback 
(Output type required: Open drain 
or 5V+/-5%) 
18  Blue / Red 
WIEGAND_LEDOUT2 
In 
Wiegand LED IN 2 (option): panel 
feedback 
(Output type required: Open drain 
or 5V+/-5%) 
20  Black / Red 
WIEGAND_GND 
 
Ground for Wiegand 
 
The use of LED IN 1 and LED IN 2 wires is described in the paragraphs below.