Section 4 : Electrical Interface 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
38 
June 2015 
 
 
Data Clock Input 
The  following  figure  shows  how  to  cable  the  wires  of  the  “Wiegand  In”  port  of  the 
terminal  for  Data  Clock  protocol.  This  is  used,  for  instance,  to  connect  an  external 
card stripe reader to the MorphoAccess® SIGMA Lite terminal. 
 
  
Figure 16: Wiegand port wiring – DataClock 
13  Green / Red  WIEGAND_IN0 
In 
Data (Output type required: 
Open drain only) 
15  White / Red  WIEGAND_IN1 
In 
Clock (Output type required: 
Open drain only) 
17  Blue 
WIEGAND_LEDOUT1 
Out 
Card present signal (if configured, 
only one selectable for Morpho 
Legacy) 
18  Blue / Red 
WIEGAND_LEDOUT2 
Out 
Card present signal (if 
configured) 
20  Black / Red 
WIEGAND_GND 
 
Ground for Wiegand