Section 4 : Electrical Interface 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
40 
June 2015 
 
 
RS-485 port wiring 
The  following  figure  shows  how  to  cable  the  wires  of  the  RS-485  OUT  port  of  the 
terminal (RS-485 protocol). This is used, for instance, to connect the MorphoAccess® 
SIGMA Lite terminal to an Access Control Panel (ACP). 
 
  
Figure 18: RS-485 port wiring – RS485 
Blue 
RS485_A 
In/Out  RS485 Rx/Tx non inverting signal 
Blue / Red 
RS485_B 
In/Out  RS485 Rx/Tx inverting signal 
Black / Red 
RS485_GND 
 
Ground 
RS485 implementation is limited to half-duplex communication. So only Tx+, Tx- and 
ground reference signals are necessary. 
Depending on the RS485 network, an impedance adaptation may be required. 
For  farthest  terminal,  a  120-Ohms  resistor  termination  may  be  added  outside  the 
terminal between Tx+ and Tx-.