DSV2+
Turbo
 User Manual, Version 1.09 
32 
Copyright © 2006 by Datastrip, Inc.  All rights reserved.   
Reproduction in whole or in part is prohibited. 
  Select most recent appropriate source file (Ex.  Src File: \DSVII_0195_sh4.CAB) 
  Click Download and wait for message “Download complete” 
  Click Update 
  Click Reboot 
  Power up unit 
  The DSV2+ registration program will automatically open.  Select the button for the 
device that you are registering (DSVII-SC, DSVII-PA, or DSVII-SW).  Select [OK] and 
wait.  (This process can take from a few seconds to up to 45 seconds). 
  Click [Ok] in the “Hurray!” Box when it appears, then close the application window. 
  Double tap My Computer and Select Storage Card / DSVII. 
  Double tap the RegistrySaver program. 
  Double tap the PPCalFt41utility and press the “Calibrate” button to initialize the 
fingerprint sensor.  This process may take up to a minute and then a “green” window with 
a number “1” should appear to indicate the sensor was successfully calibrated.  
  Double tap the DsVerifyFpCaptureTest application. In the lower right hand corner select 
“UPEK” and click “OK”.  DO NOT use the calibrate button on this screen for UPEK, 
however you can use the Scan function to test the fingerprint image. 
  If you are upgrading a scanner go to Section 8.2 
 
8.2  Loading Scanner Firmware Updates 
The DsVerify2ScannerUpdate utility is used to update the DSP firmware in the scanner-based 
versions of DSV2+ by installing runtime files of the proper form (.hex extension) which have 
been generated by Datastrip.   
  Check that the Scanner Firmware provided is compatible for use with the unit by looking 
at the DSVII Software Release Notes for the Run-Time software.  The version of the 
scanner firmware can be checked in the DatastripDsVerify2About application under the 
name “ScanVer”. 
  In the directory Storage Card/DSVII run the utility DsVerify2ScannerUpdate.exe. 
  Using the button marked […]; select by, double clicking, the appropriate scanner runtime 
DSP binary file (.hex) that is to be loaded into the scanner sub-system.  The latest copy is 
usually found in the Storage Card -> DSVII -> DSVII_Scanner_DSP directory. (Ex.  Src 
File: \DSVII_Scanner_Runtime_Ver_152.Hex) 
  Once the appropriate file has been chosen, click the Verify button to validate the format 
and checksums for the file.   
  Click the Update button to download the file to the scanner DSP engine. 
  When the status message indicates “Scanner Update Complete”, Exit the application. 
  To confirm the new version has been loaded use the DatastripDsVerify2About.exe 
application to check the “ScanVER” entry, which should match the release number of the 
(.hex) file that was just loaded. 
  Reboot the unit by pressing Power Off button.  
 
8.3  Loading Smartcard Firmware Updates 
Smartcard firmware version 5.12 cannot be erased and therefore does not support the update 
procedure.  Only ScardFw versions 6.32 or later can be updated. Verify the version of your 
SCardFw by running the DsVerify2About Utility. The procedure for updating the smartcard 
firmware is as follows: