Справочник Пользователя для Aclara Power-Line Systems Inc. Y72553-1

Скачать
Страница из 86
62
T W A C S
®
- O R I O N
®
  f o r   U M T   P r o d u c t s   U s e r   G u i d e
EMTR-3 Diagnostic Indicators
If you are unable to resolve a problem with the TWACS
® 
ORION
®
 system, return 
instructions.
Record Overwrite Warning
The Record Overwrite Warning displays when you attempt to install or delete an 
IED, perform an RCE Change Out, or select Manage Listen Mode when there are 
an insufficent number of database records available.
There are two Record Overwrite Warnings. The first Record Overwrite Warning 
can be seen below.
Press any key to view the second Record Overwrite Warning.
Press 
ESC
 to return to the originating list, or press 
Enter
 to continue the operation 
and overwrite the existing records.
104 RFPIC Sent Invalid 
Response. . .
The RFPIC sent an invalid 
response to the UI. The HHTR-3 
UI processor didn't recognize the 
response from the RF PIC. 
 
Retry the command.
105 Operation Cancelled
Indicates the Esc button was 
pressed during an operation. 
Continue to desired action.
221 Install Failed
The HHTR was unable to install 
the IED.
Retry the command
222 Removal Failed
The HHTR was unable to remove 
the IED.
Retry the command
223 Extract Failed
The HHTR was unable to extract 
the port list from EMTR.
Retry the command
230 PC Upload Incomplete
The PC upload operation was 
aborted by the operator or there 
was a communication timeout.
Resolve any 
communication errors. 
Check cable. Ensure PC 
application is functional. 
Retry the command.
Error
Description
Solution
Warn: Database Full
Upload Data to PC
Press Any Key
Warn: Database Full 
Continue Operations &
Overwrite Records?
ESC: No,  Enter: Yes
DRAFT