Справочник Пользователя для RadioFrame Networks Inc MCSERIESHP10

Скачать
Страница из 131
Management—Datafill, Configuration and Optimization   
MC-Series High-Power System 
  
998--01 
Rev 
X1 
74 
CONFIDENTIAL AND PROPRIETARY 
RadioFrame Networks, Inc. 
 
TRADE SECRET INFORMATION 
Figure 49  System Parameter Information Page  
 
Note:  The datafill parameters “hdvrCINROutboundThreshold” and 
“rconCINROutboundThreshold” are modified in the iSC per the iDEN specification. 
The value displayed as “rsel_threshold” in the System Parameter Information page 
reflects the observed BCCH value, which is the datafill value of 
“rconCINROutboundThreshold”, offset by + 14 dB. The value displayed as 
“hdvr_threshold” is the datafill value “hdvrCINROutboundThreshold”, offset by  
+ 14 dB. For example, in the screen shot shown in Figure 49, the datafill value 
corresponding to “hdvr_threshold” would be equal to 6 (i.e., 6 +14 = 20). 
System Manager is the MC-Series system web-based interface. System Manager 
provides status, performance, and alarm information for the MC-Series system and its 
components, as well as diagnostic tools and online help. When new releases of System 
Manager are provided, download the new release as described in section 8.1 “Upgrading 
MC-Series System Software”. 
If any of the following information is changed in System Manager, also note those 
changes on the Equipment Inventory or site as-built documentation: 
• Physical location 
• IP addresses