MC-Series High-Power System 
 
Scheduled and Unscheduled Maintenance 
998--01 Rev X1 
RadioFrame Networks, Inc. 
CONFIDENTIAL AND PROPRIETARY 75 
 
 
• Port connections 
• Sector locations 
7  Scheduled and Unscheduled Maintenance 
7.1  Maintenance 
A report of the MC-Series High-Power system should be maintained and left on site. This 
report will provide metrics for possible concerns with individual components and/or the 
entire system. It is important that the technician performing the checks understand the 
equipment theory and operation. Review the documentation (references) prior to 
verification and performing service. 
For non-RFN hardware, refer to the equipment manufacturer’s documentation for 
maintenance information and procedures. For the iSC-3s and the EAS, refer to the Gen 3 
Site Controller System Manual
, Motorola, 68P80801E30-O. For the CSU, refer to the 
manufacturer's documentation for preventive maintenance information. 
7.2  Annual Maintenance 
Conduct the following 
annual maintenance
•  Visually inspect all equipment in the MC-Series High-Power system cabinet for 
loose or foreign items and for visible damage.  
•  Verify site-configuration cabling is correct. Refer to cabling diagrams in Appendix C. 
•  Conduct the BER test on each RadioBlade transceiver. Refer to Appendix F “BER 
Test Procedure”. 
•  Conduct the TOR Tx measurement (RF output measurement) on each transmitter.  
7.3  Troubleshooting Guidelines 
Technicians should conduct the following troubleshooting steps in order: 
1  Visually inspect for fault indication (LEDs).  
2  Inspect the Alarm Manager, and follow alarm resolution procedures. Refer to the 
Alarm and Event Guide as well as sections 7.5 “System Manager Alarms” and 7.6 
“RadioBlade Transceiver Alarm Handling” of this Implementation Guide. 
3  Contact the RadioFrame Networks Technical Assistance Center at: (800) 328-0847. 
Also, refer to section 1.3, “Repair and Technical Support” on page 12. 
4  Complete and save the serial log upload if directed; refer to section 7.7 “Serial Log 
Upload Procedure”. 
5  Refer to sections 7.8, ”Power Down Procedure” and 7.9, “Field Replaceable Unit 
(FRU) Procedures” as necessary. 
7.4  Fault Indications 
This section provides fault indications for the following RadioFrame Networks 
components only: BIC, AIC, RBS and RF Shelf. For all non-RFN equipment, refer to 
Sprint Nextel’s or the manufacturer’s documentation.