USER MANUAL FOR MBDA-200S 
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 28 
 
 
 
 
 
3.5.3  mBDA CONNECTIONS 
Step1: Connect the mBDA DT port to the RF Source downlink, and then connect mBDA MT port with RF 
Source uplink.  
 
Step 2: Connect the power cable to the power supply port (100-240VAC, 1Amp maximmum). 
 
 
Figure 22: mBDA Power Connection (Rear Panel) 
 
 
3.5.4  EXTERNAL ALARM CONNECTION  
For EXT-ALM, this is a 4-pin connector. The following figure and table show the pin allocation and 
definition. Pin numbering are shown looking-into the connector on the enclosure.  
1
2
3
4
 
Figure 23:  
Pins Allocation for “EXT_ALM” Port for mBDA 
 
Table 4
: Pin Definition of “EXT_ALM” Port for mBDA 
Pin number 
Alarm definition 
EXT. Alarm 1 
GND 
EXT. Alarm 2 
GND 
 
Note: Users need to configure Ext Alm 1~2 on WEB GUI to realize External Alarm (Refer to Chapter 5).  
 
3.5.5  CONNECT TO PC 
The local commissioning and management for mBDA is achieved through connecting to the WEB based 
GUI. 
 
Connect mBDA to PC 
 
Connect mBDA 
“OMT” port (RJ45) to the RJ45 port of PC with supplied Ethernet cable to achieve local 
monitoring and management.  
 
End of Section
 