RK-Wi.232FHSS-25-FCC Rapid Development Kit 
User’s Manual
 
 
© 2002-6 Radiotronix Inc, all rights reserved
  - 4 - 
3/27/2006 
 
3  Using the RK-Wi.232FHSS-FCC Evaluation Software 
The software supplied with the RK-Wi.232FHSS-25-FCC
™ RadKit is used to read and set the volatile and 
non-volatile registers with the Wi.232FHSS-25
™ module. Refer to the Wi.232FHSS™ User’s Manual for 
more information on the register settings.  
 
3.1 Module 
Selection 
The RK-Wi.232FHSS-FCC
™ evaluation software supports both 
the 25mW and 250mW versions of frequency hopping modules.  
Select the Wi.232FHSS-25
™ module type. 
 
 
 
3.2  COM Port Setup and Selection. 
Upon starting the RK-Wi.232FHSS-FCC
™ evaluation software, you 
will be presented with a COM port selection dialog box. If you are 
using the USB interface, make sure that the evaluation board is 
already connected to the computer via the USB cable before you 
start the software. This will ensure that the virtual COM port which is 
assigned to the USB to UART bridge controller by Windows is visible 
in the COM port selection list. 
The first time you start the RK-Wi.232FHSS-FCC
™ evaluation 
software, the Baud Rate should be left at 2400 baud, since this is the 
factory default baud rate setting for the module. 
Tip: The RK-Wi.232FHSS-FCC
™ evaluation software does not auto-
detect the baud rate of the module. If you have changed the Non-
Volatile Data Rate register, you will have to select the baud rate you 
set this register to when you start the RK-Wi.232FHSS-FCC
™ 
evaluation software.