Step 5 Label the installed cables according to the instructions in Attaching an L-Shaped Label.
----End
9.9 Opening the Cover Plate of an RRU Cabling Cavity
This section describes the procedure for opening the cover plate of an RRU cabling cavity.
Procedure
Step 1 Wear ESD gloves.
CAUTION
Take proper ESD protection measures, for example, wear ESD gloves, to prevent electrostatic
damage to the boards, modules, or electronic components.
Step 2 Use an M5 Phillips screwdriver to loosen the three screws on the cover plate of the RRU cabling
cavity, and open the cover plate, as shown in 
Figure 9-19 Opening the cover plate of the RRU cabling cavity
(1) Cover plate
(2) Cabling cavity
(3) Clip
(4) Cable trough for the power cable
(5) Waterproof block
(6) Cable trough for the fiber optic cable
 
Step 3 Loosen the screws on the clip, and open the clip, as shown 
.
RRU3260
Installation Guide
9 Installing RRU Cables
Issue ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
111