Справочник Пользователя для AeroComm Corporation 2510100

Скачать
Страница из 34
3
LT2510 User’s Manual
S P E C I F I C A T I O N S
LAIRD TECHNOLOGIES www.lairdtech.com
P I N   D E F I N I T I O N S
The LT2510 has a simple interface that allows OEM Host communications with the transceiver. Table 2  below shows the
connector pin numbers and associated functions.
Certifications
FCC Part 15.247
KQL-2510100
Industry Canada (IC)
2268C-2510100
CE
Pending
Ta b l e   2 :   P i n   D e f i n i t i o n s   f o r   t h e   LT 2 5 1 0   t r a n s c e i v e r
SMT Pin
Type
Signal Name
Function
1
O
 GO_0
Generic Output
2
O
GO_1
Generic Output
3
DNC
Do not connect.
4
Reserved for future use
5
O
PWM_Output
PWM Digital to Analog Output
6
I
RXD
Asynchronous serial data input to transceiver
7
O
TXD
Asynchronous serial data output from transceiver
8
GND
GND
Signal Ground
9
PWR
VCC
3.3 - 3.6 V ±50mV ripple (must be connected)
10
PWR
VPA
3.3 - 3.6 V ±50mV ripple (must be connected)
11
GND
GND
Signal Ground
12
I
Test
Test Mode – When pulled logic Low and then applying power or resetting, the trans-
ceiver’s serial interface is forced to a 9600, 8-N-1 rate. To exit Test mode, the trans-
ceiver must be reset or power-cycled with Test Mode pulled logic High or left 
floating/disconnected.
Note: Because this mode disables some modes of operation, it should not be perma-
nently pulled Low during normal operation.
13
Reserved
Reserved for future use
14
I
UP_Reset
RESET – Controlled by the LT2510 for power-on reset if left unconnected. After a sta-
ble power-on reset, a logic Low pulse will reset the transceiver.
15
I
CMD/Data
When logic Low, the transceiver interprets OEM Host data as command data. When 
logic High, the transceiver interprets OEM Host data as transmit data.
Ta b l e   1 :   LT 2 5 1 0   D e t a i l e d   S p e c i f i c a t i o n s