Troubleshooting 
8-1 
DIAD 6 Charge Rack Manual 
 
 
 
 
 
 
Troubleshooting 
 
Symptoms 
Cause 
Suggested Action 
Terminal LED not illumi- 
nated on a single bay. 
Terminal not seated properly 
Verify that the terminal is pressed firmly 
into the bay. 
Defective terminal 
Verify that the terminal LEDs do not 
illuminate in a known good bay.  If nec- 
essary, send the terminal for repair. 
Dirty I/O pins and/or terminal 
charge contacts 
Inspect the I/O pins and terminal charge 
contacts for dirt.  Clean the pins and ter- 
minal charge contacts using the 
approved cleaning method (see page 
). 
Broken I/O pins 
Inspect the I/O pins for damage.  If nec- 
essary, replace the I/O board with kit 
part #50142380-001FRE (see page 
). 
I/O board power cable failure 
Verify that the I/O cable is properly 
inserted.  If necessary, replace the I/O 
cable with kit part #50142485-001FRE 
(see page 
). 
I/O board failure 
Replace the I/O board with kit part 
#50142380-001FRE (see page 
). 
Power distribution board fail- 
ure 
Replace the power distribution board 
with kit part #50142378001FRE (see 
page 
). 
Terminal LED not illumi- 
nated on an entire bank of 
six bays. 
Big harness failure/connec- 
tion issue 
Verify that the big harness is properly 
connected to the power distribution 
board.  If necessary, replace the big har- 
ness with kit part #200004056CNRKIT 
(see page 
). 
Power distribution board fail- 
ure 
Replace the power distribution board 
with kit part #50142378001FRE (see 
page 
).