Справочник Пользователя для Adtran TRC6420
Section 5 User Interface Guide
TRACER 6420 System Manual
52
Copyright © 2005 ADTRAN, Inc.
612806420L1-1A
> RF L
INK
C
ONFIGURATION
Figure 5 shows the TRACER 6420 RF Link Configuration screen, which contains the transmit and receive
power settings and band plan configuration for both the local and remote units.
power settings and band plan configuration for both the local and remote units.
Figure 5. RF Link Configuration
> RF L
INK
C
ONFIGURATION
> RX P
OWER
Displays the approximate receiver levels (for both the local and remote units) using a series of symbols (
#
).
The more symbols (
#
) displayed, the stronger the signal. If the link is down in either direction and remote
end data is unavailable,
D
ATA
N
OT
A
VAILABLE
displays in place of the symbols (
#
). This parameter is
display only.
> RF L
INK
C
ONFIGURATION
> TX P
OWER
Allows the transmitter levels (for both the local and remote units) to be adjusted. The current transmitter
level is displayed using a series of symbols (
level is displayed using a series of symbols (
#
). The more symbols (
#
) displayed, the stronger the signal. If
the link is down and remote end data is unavailable,
D
ATA
N
OT
A
VAILABLE
displays in place of the symbols
(
#
). Pressing (+) on this field sets the
T
X
P
OWER
to full strength; pressing (-) reduces the
T
X
P
OWER
to the
minimum.
Reducing the transmitter power of the remote TRACER 6420 could cause the RF link to
drop, requiring a technician to increase the transmit power by using the menu system at
the remote site.
drop, requiring a technician to increase the transmit power by using the menu system at
the remote site.