> RF L
INK
 C
ONFIGURATION
Figure 5 shows the TRACER 6420 RF Link Configuration screen, which contains the transmit and receive 
power settings and band plan configuration for both the local and remote units.
Figure 5.  RF Link Configuration
> RF L
INK
 C
ONFIGURATION
 > RX P
OWER
Displays the approximate receiver levels (for both the local and remote units) using a series of symbols (
#
). 
The more symbols (
#
) displayed, the stronger the signal. If the link is down in either direction and remote 
end data is unavailable, 
D
ATA
 N
OT
 A
VAILABLE
 displays in place of the symbols (
#
). This parameter is 
display only. 
> RF L
INK
 C
ONFIGURATION
 > TX P
OWER
Allows the transmitter levels (for both the local and remote units) to be adjusted. The current transmitter 
level is displayed using a series of symbols (
#
). The more symbols (
#
) displayed, the stronger the signal. If 
the link is down and remote end data is unavailable, 
D
ATA
 N
OT
 A
VAILABLE
 displays in place of the symbols 
(
#
). Pressing (+) on this field sets the 
T
X
 P
OWER
 to full strength; pressing (-) reduces the 
T
X
 P
OWER
 to the 
minimum. 
Reducing the transmitter power of the remote TRACER 6420 could cause the RF link to 
drop, requiring a technician to increase the transmit power by using the menu system at 
the remote site.