Справочник Пользователя для Adtran TRC6420
TRACER 6420 System Manual
Section 5 User Interface Guide
612806420L1-1A
Copyright © 2005 ADTRAN, Inc.
55
The link error count and minimum received signal level for the most recent 24 hours are recorded in
15-minute increments and displayed on the right side of the page. The left side of the page displays the 24
hour totals for the most recent 7 days.
15-minute increments and displayed on the right side of the page. The left side of the page displays the 24
hour totals for the most recent 7 days.
> RF L
INK
M
AX
/M
IN
R
ECEIVED
P
OWER
H
ISTORY
Figure 9 shows the TRACER 6420 RF Link Max/Min Received Power History page, which displays the
available received power statistics from the system. Minimum and maximum received signal levels for the
RF link (from both the local and remote TRACER 6420 units) in 15-minute and 24-hour increments are
found on this screen.
available received power statistics from the system. Minimum and maximum received signal levels for the
RF link (from both the local and remote TRACER 6420 units) in 15-minute and 24-hour increments are
found on this screen.
Figure 9. RF Link Max/Min Received Power History
The received power level (
MIN
and
MAX
) represents the minimum and maximum values of received signal
level in a 24-hour or 15-minute increment and is displayed as a numerical value from 0 to 100, with 0
corresponding to 0 V of RSSI and 100 corresponding to 5 V RSSI.
corresponding to 0 V of RSSI and 100 corresponding to 5 V RSSI.
Press <n> to view the next 8 hours worth of 15-minute totals and <p> to view the previous
8 hours.
8 hours.
The minimum receive power level is recorded to aid in troubleshooting problem RF links.
Radio links with high
Radio links with high
MIN
numbers and intermittent performance are probably
experiencing interference, while links with low
MIN
numbers have improperly engineered
paths or excess system losses. A system with
MIN
numbers varying widely could indicate
fading, reflections, or an intermittent installation problem such as loose connectors,
damaged coax or lightning arrestors, or water contaminated feedlines.
damaged coax or lightning arrestors, or water contaminated feedlines.
Press <n> to view the next 8 hours worth of 15-minute totals and <p> to view the previous
8 hours.
8 hours.
7
Days
24
Hours
(8 Hrs
Displayed
at a Time)
Displayed
at a Time)