Chapter 5
Operating
2100.4400.32
- 5.71 -
E-2
7.2
TV Settings > DVB > TPS
Selection of TPS source
The TPS Source switch is used to select the source for the TPS parameters:
– MIP: The TPS information is to be retrieved from the MIP
– Manual Presets: The TPS parameters are to be configured manually
Note
If the system is in MFN mode and the MIP drops out when MIP has been selected as the
TPS source, the system continues transmission using the last known MIP values.
Configuration of TPS parameters
TPS parameters classified as Manual can be configured. These manual settings become
active if Manual Presets is selected as the TPS source.
If MIP is selected as the TPS source, the TPS information is retrieved from the MIP. If the
MIP fails, the system attempts to continue transmission using the last known configuration.
If the instrument is restarted, at least one MIP packet must be received for the configuration
to be known.
Tx Address
Used to set the transmitter address; address range: 0 to 65535
Setting the transmitter address is a precondition to reading Tx informa-
tion (transmitter-specific settings) from the MIP. However, the informa-
tion is only used if Tx Automatic is enabled.
Tx Automatic
Used to switch Tx Automatic on or off
If Tx Automatic is activated (and the transmitter address is set), the fol-
lowing Tx parameters are retrieved from the MIP:
Time Offset, Frequency Offset and Cell ID
Display
Explanation
Amplifier Control
Indicates the status of amplifier control
Setting item