Справочник Пользователя для Rohde & Schwarz Inc SLV8000

Скачать
Страница из 328
Chapter 5
Operating
2100.4400.32
- 5.78 -
E-2
7.5
TV Settings > DVB > Test Signals
The Test Signals menu window is used to generate test signals.
Setting item
Description
PRBS Insertion
Insertion of a PRBS sequence instead of the transport stream present at 
the input
Selection:
– OFF: Normal operating status, test sequence not active
– 2^23-1, 2^15-1 or 2^9-1: Displayed PRBS sequence selected
Test Signal Insertion
Insertion of unmodulated test carriers or suppression of modulated car-
rier ranges in the output frequency spectrum
Selection:
– OFF: Normal operating status, test signal not active
– CARRIER 1: Insertion of an unmodulated test carrier at carrier 
position 1
– CARRIER 2: Insertion of an unmodulated test carrier at carrier 
position 2
– C1 and C2: Insertion of two unmodulated test carriers at carrier 
position 1 and carrier position 2
– BANDPASS: Suppression of the modulated carriers from position 0 to 
carrier position 1 and from carrier position 2 to the end of the fre-
quency spectrum
– BANDSTOP: Suppression of the modulated carriers in the range 
between carrier position 1 and carrier position 2
In the BANDPASS and BANDSTOP functions, the value for carrier 1 
must be smaller than the value for carrier 2.
Carrier 1
Sets the position for test carrier 1
Carrier 2
Sets the position for test carrier 2