Справочник Пользователя для Rohde & Schwarz Inc SLV8000
Chapter 5
Operating
2100.4400.32
- 5.106 -
E-2
– Transmitter: Used to select the TV standard, to activate message suppression for the
parallel remote interface, to determine the behavior of the parallel remote interface when
switching between analog TV and digital TV, to activate the time scheduler for multistan-
dard operation and to enter the transmitter name
switching between analog TV and digital TV, to activate the time scheduler for multistan-
dard operation and to enter the transmitter name
– Configuration: Used to select and configure the TV standards for time-controlled
switchover
– Time Scheduler: Used to define switching times for time-controlled switchover of the
standards
11.6.1
System Setup > Tx Type > Transmitter
The System Setup > Tx Type > Transmitter menu window is used among other things to
set the input interfaces and signal processing the appropriate TV standard. You can also
activate a time scheduler for multi-standard operating mode and enter special settings for
the parallel remote control interface.
set the input interfaces and signal processing the appropriate TV standard. You can also
activate a time scheduler for multi-standard operating mode and enter special settings for
the parallel remote control interface.
Setting item
Explanation
Tx Type
Used to select the TV standard: ATV, DVB or ATSC
The instrument is rebooted automatically when the TV standard is
changed. Signal processing is also switched over.
changed. Signal processing is also switched over.
Reset On Program
Off
Off
In the ON switch position, a Reset Fault is automatically triggered when
the RF output is locked.
the RF output is locked.
Time Scheduler
Used to switch time-controlled tasks planned using the time scheduler
on and off
on and off
Par I/O DTV setting
The parallel remote interface can be used to switch from ATV to DTV.
The switch determines which standard is used for DTV.
The switch determines which standard is used for DTV.
Par I/O Inhibit Status
Used to switch message suppression for the parallel remote interface on
and off
and off
– OFF: Message suppression is not activated; messages carried by the
parallel remote interface are also output in local mode
– ON: Message suppression is activated; in local mode, no messages
are output via the parallel remote interface
Tx Name
Used to enter a transmitter name to make identification easier