Справочник Пользователя для Rohde & Schwarz Inc SLV8000

Скачать
Страница из 328
Chapter 4
Commissioning
2100.4400.32
- 4.10 -
E-2
2.2.2.4
Configuring Input Interfaces and Automatic Input Selection
Setting signal source and data format for transport streams
1. Select TV Settings > Input > Input Config.
The Input Config window opens.
2. Under Source 1, set the signal source for transport stream 1:
a) Select BNC if transport stream 1 is fed via the instrument socket for 
TS1
.
or
b) Select Rx if transport stream 1 comes from the internal receiver module (DVB-T/-H
receiver option).
3. Under TS Format 1, select the data format for transport stream 1. If AUTO is selected,
the data format is detected automatically.
Note
With hierarchy, the first signal source supplies the HP stream.
4. If necessary (signal standby, LP stream with hierarchy), configure a second transport
stream accordingly under Source 2 and TS Format 2.
Note
Transport stream 2 can be fed via either the instrument socket for 
TS2
 or a (second) op-
tional receiver module.
Setting automatic input switchover (not with hierarchy)
The following settings are used to preselect the operating input and to configure the behav-
ior of the automatic input switchover.
Setting item
Explanation
Static Delay
Positive or negative offset (set manually for the individual transmitter 
location) of the time of transmission relative to the regular time of trans-
mission preset under Maximum Delay. The Static Delay is used to com-
pensate differences between transmission systems from different 
manufacturers.
If Static Delay and Tx Offset Delay are present at the same time, their 
effect is added together.
Max Deviation Time
Maximum deviation in the calculated time of transmission which can be 
corrected without interrupting transmission.
Default setting: 10 
s